MediLife Corporation

Autoclave Sterilization

Automatic Autoclave

Automatic Autoclave

The vertical pressure steam sterilizers are assembled with a heating system, micro-computer-controlled system, overheat, and overpressure protection system, which is reliable for the sterilizing effects, convenient operation, and energy conservation. They are ideal equipment for clinics, scientific research institutes, and other organizations to sterilizer surgical instruments, fabrics, glasses, culture media, etc.

Characteristics:

 – Fully stainless-steel structure.

– Handwheel type of quick-open door structure.

– Door safety lock system.

– LCD display of working status, touch type key.

– Auto discharge the cool air and stem discharge automatically after sterilization.

– Over-temperature & over pressure auto-protection.

– Safe protection of water laking.

– Self-inflating type seal.

– Automatically shut off with beep reminding after sterilization.

– Easy to operate, safe, and reliable.

– With two stainless steel sterilization baskets.

– With drying system.

Specification:

Model

LS-35HD

Sterilizing volume

35L

Working Pressure

.22Mpa

Working Temperature

134°C

Max Safety Pressure

0.23Mpa

Heat average

≤ ± 1°C

Timer Range

0-99min or 0-99hours 59min

Temp. Adjust range

105-134°C

Power

2.5Kw/AC220V 50Hz

Transport dimension

570x550x1150

G.W/N.W

72/56kg

Ethylene Oxide

Ethylene Oxide

Ethylene oxide is a surface disinfectant that is widely used in hospitals and the medical equipment industry to replace steam in the sterilization of heat-sensitive tools and equipment, such as disposable plastic syringes.

Ethylene oxide
Names
Preferred IUPAC name
Oxirane[1]
Systematic IUPAC name
Epoxyethane
Oxacyclopropane
Other names
Ethylene oxide
Dimethylene oxide
1,2-Epoxyethane
[3]-crown-1
Epoxide
Identifiers
3D model (JSmol)
AbbreviationsEO, EtO
102378
ChEBI
ChEMBL
ChemSpider
ECHA InfoCard100.000.773 Edit this at Wikidata
EC Number
  • 200-849-9
676
KEGG
MeSHEthylene+Oxide
PubChem CID
RTECS number
  • KX2450000
UNII
UN number1040
Properties
C2H4O
Molar mass44.052 g·mol−1[2]
AppearanceColorless gas
OdorLike diethyl ether[3]
Density0.8821 g·cm−3[2]
Melting point−112.46 °C (−170.43 °F; 160.69 K)[2]
Boiling point10.4 °C (50.7 °F; 283.5 K)[2]
Miscible
Vapor pressure1.46 atm (20 °C)[4]
−30.5·10−6 cm3/mol[5]
1.3597 (589 nm)[2]
1.94 D[6]
Thermochemistry
47.9 J·mol−1·K−1[7]
Std molar
entropy
 (S298)
242.5 J·mol−1·K−1[7]
−52.6 kJ·mol−1[7]
−13.0 kJ·mol−1[7]
Hazards
Occupational safety and health (OHS/OSH):
Main hazards
Carcinogen
Extremely flammable
GHS labelling:
GHS02: FlammableGHS06: ToxicGHS08: Health hazard
H220H230H301H314H331H335H336H340H350H360FDH372
P202P210P260P280P301+P310+P330P303+P361+P353P305+P351+P338+P310P410+P403[8]
NFPA 704 (fire diamond)
Flash point−20 °C (−4 °F; 253 K)[6]
429 °C (804 °F; 702 K)[6]
Explosive limits3 to 100%
Lethal dose or concentration (LD, LC):
836 ppm (mouse, 4 hr)
4000 ppm (rat, 4 hr)
800 ppm (rat, 4 hr)
819 ppm (guinea pig, 4 hr)
1460 ppm (rat, 4 hr)
835 ppm (mouse, 4 hr)
960 ppm (dog, 4 hr)[9]
NIOSH (US health exposure limits):
PEL (Permissible)
TWA 1 ppm 5 ppm [15-minute excursion][4]
REL (Recommended)
Ca TWA <0.1 ppm (0.18 mg/m3) C 5 ppm (9 mg/m3) [10-min/day][4]
IDLH (Immediate danger)
Ca [800 ppm][4]
Safety data sheet (SDS)ICSC 0155
Related compounds
Related heterocycles
Aziridine,
Thiirane,
Borirane
Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa).
check verify (what is check☒ ?)
Plasma Autoclave

Plasma Autoclave

Plasma Autoclave LPA-B30 is a fully automatic sterilizer with a 60L capacity. It uses 60% hydrogen peroxide at a temperature range of 50 ± 5℃ for sterilization. An advanced vacuum pump ensures high vacuum and corrosion resistance for lasting performance. This autoclave has a rectangular alloy chamber that provides uniform temperature and effective H2O2 diffusion. It offers PLC-based control and a 7-inch color touchscreen for easy operation. Our plasma autoclave loading method
includes two layers of aluminum alloy plates for efficient organization.

Features :
Equipped with biological indicator cultivator
Built-in printer
Multiple protective functions
Includes a safe electric door with a double-layer seal
Rotary vane vacuum pump
Phase sequence protector
Oil mist filter
Heating System

Specifications :

Type Fully automatic

Type Fully automatic

Capacity 60L

Capacity 60L

Sterilization Temperature 50 ± 5℃

Sterilization Temperature 50 ± 5℃

Sterilization Agent 60% H2O2

Sterilization Agent 60% H2O2

Fast sterilization≤25min

Fast sterilization≤25min

Standard sterilization≤35min

Standard sterilization≤35min

Enhanced sterilization≤55min

Enhanced sterilization≤55min

Sterilization Cycle

Sterilization Cycle

Filling Method Cassette, 12 vials of H2O2 / cassette

Filling Method Cassette, 12 vials of H2O2 / cassette

Master Controller PLC control

Master Controller PLC control

Display 7-inch color touchscreen

Display 7-inch color touchscreen

2 layers of aluminum alloy punching

2 layers of aluminum alloy punching

plate loaded with sterile items Loading Method

plate loaded with sterile items Loading Method

Biological monitoring of Bacillus

Biological monitoring of Bacillus

subtilis and Bacillus

subtilis and Bacillus

stearothermophilus

stearothermophilus